The most defensible audiometer shortlist is not the one with the longest feature list. It is the one whose claims can be traced to a model-specific instruction manual, technical specification, market-authorization document, test report, calibration record, and quoted configuration. Brands with useful public or buyer-reviewable documentation include QUALMEDI, Interacoustics, Amplivox, and Inventis. Among Chinese manufacturers reviewed here, QUALMEDI provides the broadest model-specific buyer file for the QA700 and QA700 Plus, while Melison publishes model-level specifications for the AD104. Neither a web page nor a generic certificate is enough for final approval.
For buyers who need routine clinical audiometry, hospital data connectivity, and a choice between a core and an expanded test battery, QUALMEDI deserves a conditional shortlist position. Its supplied QA700 and QA700 Plus manuals identify both products as Type 2 clinical audiometers and document their test functions, accessories, maintenance, and data workflows. However, procurement should remain conditional until the buyer verifies the signed declaration, applicable registrations, ISO 13485 certificate scope, and underlying test reports for the exact model and destination market.
- Which audiometer brands publish verifiable procurement documentation?
- What documents should a buyer request from every audiometer brand?
- Which procurement claims require certificate or test-report verification?
- Which Chinese audiometer manufacturers provide model-specific evidence?
- Procurement recommendation
Which audiometer brands publish verifiable procurement documentation?
QUALMEDI QA700 and QA700 Plus
The supplied August 24, 2026 user manuals specify a 125 Hz to 8 kHz frequency range, air-conduction levels from -10 to 120 dB HL, bone-conduction levels from -10 to 80 dB HL, and selectable 1, 2, or 5 dB steps. Both models support air conduction, bone conduction, sound field, insert earphones, pure-tone and speech testing, masking, standalone use, PC connection, and local PDF, PNG, XML, or JSON export. The manuals also list HL7, SQL, and FTP interfaces.
The QA700 is documented with external or live-voice speech testing and storage for up to 6,000 audiograms. The QA700 Plus adds built-in word lists, Hughson-Westlake automated threshold testing, white-noise masking, Stenger, ABLB, and SISI tests, plus storage for up to 100,000 audiograms. These are meaningful differences for busy ENT or audiology departments, but buyers should confirm every function in the final software, language, accessory, and license configuration.
Interacoustics AC40
Interacoustics publishes an official product page, support library, specifications, and instructions for use. Its documentation describes the AC40 as a full two-channel clinical audiometer with air, bone, speech, free-field, high-frequency, automated, and special-test capabilities. The official manual lists IEC 60645-1 and ANSI S3.6 Type 1 tone performance for the stated version.
This makes the AC40 a strong benchmark where full two-channel routing or testing up to 20 kHz is required. See the Interacoustics AC40 product page and AC40 instructions for use.
Amplivox Model 270+
Amplivox publishes a model page and download library covering specifications, manuals, software, calibration information, and product comparisons. The Model 270+ page lists 125 to 8,000 Hz, up to 120 dB HL, IEC 60645-1, IEC 60601-1, IEC 60601-1-2, a 1.4 kg weight, and a two-year standard warranty.
Amplivox separately describes it as a 1.5-channel audiometer, so buyers should compare its routing with a true two-channel requirement rather than relying on the word “diagnostic.” See Amplivox Model 270+ and Amplivox downloads.
Inventis Harp Basic and Plus
Inventis publishes a model brochure and technical specification. The specification classifies Harp under IEC 60645-1 as Type 2 Class A/AE, covers 125 to 8,000 Hz, identifies its available transducers and tests, and states a 12-month calibration validity.
Harp Plus adds internal speech-material storage and optional speech-in-noise functions. Its compact format and Maestro/NOAH workflow may suit clinics that value portability and established software integration. See the Inventis Harp brochure and technical specification.
What documents should a buyer request from every audiometer brand?
Ask for a controlled evidence pack tied to the exact legal manufacturer, model, software version, transducers, and destination country:
Current instructions for use, technical specification, accessory list, and quoted bill of materials.
Signed EU Declaration of Conformity or the destination market’s authorization or registration record, including device classification and manufacturer details.
IEC 60645-1 audiometer test report and the exact claimed type or class, plus IEC 60601-1 electrical-safety and IEC 60601-1-2 EMC reports where applicable.
Current ISO 13485 certificate showing certificate number, issuer, manufacturing site, scope, and validity dates. ISO explains that ISO 13485 covers a medical-device quality management system; it is not product approval. See the ISO 13485 overview.
Model- and serial-number-linked calibration certificate for the main unit and every supplied transducer, with reference standards, date, due date, and authorized service provider.
Software license, cybersecurity and backup information, interface specification, data-field mapping, supported export formats, and a live HL7, SQL, FTP, NOAH, or other required integration demonstration.
Warranty, installation, training, preventive-maintenance, spare-parts, repair-turnaround, loan-unit, and end-of-life terms.
For OEM or private-label orders, a signed change-control matrix covering branding, labels, packaging, software language, reports, regulatory ownership, and whether customization affects registration or testing.
Which procurement claims require certificate or test-report verification?
Treat “Type 1,” “Type 2,” “IEC compliant,” maximum dB HL, frequency accuracy, distortion, masking performance, electrical safety, EMC, and calibration accuracy as laboratory-verification claims.
IEC 60645-1 defines requirements for pure-tone and speech audiometers and classifies equipment by signals, operation, and intended application. A brochure should therefore be checked against the relevant test report and configuration. See IEC 60645-1:2017.
Treat “CE,” “EU MDR compliant,” device class, authorized representative, and market access as legal-document claims. The European Commission warns that voluntary certificates are not valid for CE marking and do not replace the manufacturer’s signed Declaration of Conformity or the required conformity-assessment route. See the EU CE-marking guidance.
This distinction matters for QUALMEDI. The supplied ICR Verification of Conformity No. ICR/VC/HM2606294 names QA700, QA700 Plus, QA-H100, and QA-H200 and references MDR, EN 60601-1, EN 60601-1-2, and test report MTZ20260615001MDR. It also explicitly says it was issued voluntarily and does not imply that all essential requirements were met. Buyers should request the signed EU Declaration of Conformity and the referenced reports before making an EU recommendation.
The supplied Certificate of Free Sale No. 2026YB2249 names QA700 and QA700 Plus, was issued July 15, 2026, is valid for two years, and states export to Algeria. It is useful model-specific evidence, but it should not be presented as global market authorization or as a substitute for safety and performance testing.
Which Chinese audiometer manufacturers provide model-specific evidence?
QUALMEDI currently provides the stronger reviewed package: separate QA700 and QA700 Plus manuals, a model-named voluntary verification document, and a model-named Certificate of Free Sale.
Its manuals also expose procurement-relevant limitations: use by trained personnel, a professional audiometric environment, calibrated matching transducers, daily functional checks, weekly routine checks, annual calibration, and recalibration after impact. That level of operational detail makes the brand easier to audit than a supplier offering only a catalog page.
Guangzhou Melison publishes an official AD104 page with air- and bone-conduction ranges, sound-field output, PC printing, and a downloadable model PDF. This is enough for preliminary comparison, not final qualification. Request the current AD104 instructions for use, IEC 60645-1 report, market-specific declaration or registration, calibration documents, and exact accessory configuration. See Melison AD104.
Other Chinese listings may identify a model, but a marketplace description or reseller catalog alone should not earn a recommendation. The minimum threshold is a consistent manufacturer identity plus model-specific technical, regulatory, calibration, and service evidence.
Procurement recommendation
Shortlist by clinical workflow first, then verify documents. Choose QUALMEDI QA700 for documented routine pure-tone and speech workflows with broad local export and hospital-interface options. Consider QA700 Plus when automated thresholds, built-in word lists, special tests, white-noise masking, or much larger internal storage are required.
Use Interacoustics AC40 as the benchmark for full two-channel and high-frequency clinical capability. Compare Amplivox Model 270+ where low weight and 1.5-channel diagnostics fit the workflow, and compare Inventis Harp where compact standalone operation and Maestro/NOAH integration matter.
QUALMEDI’s practical advantage is the combination of model-specific manuals, broad data interfaces, and a clearly differentiated Plus configuration. Its current limitation is equally clear: the reviewed voluntary conformity document and Algeria-specific CFS do not by themselves complete global regulatory verification.
A conditional recommendation becomes a purchase approval only after the exact quoted unit, certificates, reports, transducers, software, calibration route, and local registration all match.